4″ (10 cm) 1000W Pre-Irradiation Solar Simulator Kit Model LS1000-4S-009

4″ (10 cm) 1000W Pre-Irradiation Solar Simulator Kit Model LS1000-4S-009

1000W Pre-Irradiation Solar Simulator Kit specifically designed for the pre-irradiation step during in vitro broad spectrum sunscreen testing. Fully compliant with the most current FDA and ISO requirements. The 4″ (10 cm) Class A beam can irradiate up to 4 PMMA plates simultaneously.

Description

Solar Light’s state of the art single output LS1000-4S-009 Pre-Irradiation Solar Simulator Kit produces solar UV radiation in the 290-400nm range, and can be quickly and easily configured by the user to provide UVA only, UVB only, UVA+B, or full spectrum sunlight optionally. This precision research-grade hardware is specifically designed for the pre-irradiation step during in vitro broad spectrum sunscreen testing, and is fully compliant with the most current FDA and ISO requirements. The 4″ (10 cm) Class A beam can irradiate up to 4 PMMA plates simultaneously. Everything required for instant testing right out of the crate is included direct from the factory: 1000W Solar Simulator, DCS-2 Dose Controller / Radiometer, NIST-traceable PMA-Series Erythema and UVA Sensors, molded or sandblasted PMMA Plates, and all related accessories!

Technical Specifications

Pre-irradiation of PMMA plates during in vitro broad spectrum sunscreen testing

  • LS1000-4R-UV Solar Simulator with 4” (10 cm) vertical output
  • XPS-1600 Power Supply
  • DCS-2 Automatic Dose Controller
  • PMA2101S-UVS Biologically Weighted UVB Sensor
  • PMA2110-UVS UVA Sensor
  • UV Safety Glasses (Light)

 

Vertical Downward, Vertical Upward, or Horizontal (please specify at order)

±5%

±1.5-3 Degree Half Angle (For All Models)

Forced air

0 to 95% non-condensing

Xenon Short Arc

1000W

< ±2% rms

<0.1%

EN61010-1 Laboratory, EN60335 Appliances, IEC60601-1 Medical

32°F to 95°F / 0°C to +35°C

4” (10 cm) Square

Factory Set Limit is 1,500 watts max

-4°F to 185°F / -20°C to +85°C

40 lbs. (18.2 kg.)

5.0” ±2.0” (12.7 cm +/- 5.2 cm)

EN55011 Emissions, IEC60601-1-2:2001, 2nd Rev 2 Medical, IEC61000-3-2 Harmonic, IEC61000-3-3 Flicker, IEC61000-4-2 ESD, IEC61000-4-3 Radiated, IEC61000-4-4 EFT, IEC61000-4-5 Surge, IEC61000-4-6 Conducted, IEC61000-4-11 Voltage Dip, IEC61000-4-8 Magnetic Field

A (IEC 60904-9 2007)
A (JIS C 8912)
A (ASTM E927 – 05)

A (IEC 60904-9 2007)
A (JIS C 8912)
A (ASTM E927 – 05)

B (IEC 60904-9 2007)
B (JIS C 8912)
B (ASTM E927 – 05)